Skip to content
  • Career
  • Phone book
  • Events
  • MLZ Webpage
  • MLZ User Office
  • Webmail (internal)
  • Webmail ("Betrieb")
  • Intranet
  • de
  • en
  • Research Neutron Source Heinz Maier-Leibnitz (FRM II)
  • Technical University of Munich
Technical University of Munich
  • Home
  • About us
    • From "Atomic Egg" to FRM II
    • Facts & Figures
      • Auftragsvergaben
    • News & Media
      • News article
      • Films
        • Interactive panorama
      • Brochures
        • Annual Reports
        • Newsletter
      • Events
        • Open day 2024
    • Contact
  • The Neutron Source
    • Neutrons
    • Fuel elements
      • Life cycle of a fuel element
      • Disposal of fuel elements
        • FRM II fuel element
        • Storage in Ahaus
        • Secure packaging
        • Transport vehicle
        • Permits
        • Function test
        • FAQ
      • Conversion
        • What does the conversion entail
        • Objectives of the conversion
        • Who is working on the conversion?
        • Fact check
    • Reactor
      • Installations in the pool
      • Guiding the beams
        • Cooling circuits
    • Irradiation facilities
      • Rabbit Irradiation
      • Capsule Irradiation
      • Mechanical Irradiation
      • Irradiation Position in the Control Rod
      • Irradiation with fast neutrons
      • Future Mo-99 irradiation facility
    • Safety
  • Safe all round
    • Protection of persons
    • Monitoring the facility
    • Monitoring the environment
      • Discharge of C-14
  • Research
  • Medicine
    • Radioisotopes for diagnostics
    • Radioisotopes for therapy
    • Tumor irradiation
  • Industry
    • Materialanalyse
      • TUM-Expertenforen
      • VDI Fachausschuss 101
        • Bildgebende Verfahren
        • Optische Messverfahren
        • Eigenspannungs- und Texturanalyse
        • Analytik
      • Analysis with neutrons
    • Radioisotopes for industry
    • Silicon doping
  • Career
  • Guided Tours
  1. Home
  2. About us
  3. News & Media
  4. News article

Enhanced magnetization of Cobalt defect clusters embedded in TiO<sub>2−δ</sub> films for spintronic devices

Aktuell, Wissenschaft, N-REX+ | 18.04.2017


(a) The 68 nm thick amorphous TiO<sub>2</sub> thin films were synthesized with atomic layer deposition before (b) Co was implanted at low energies (20−60 keV). (c) The resulting nanostructures were studied with low-angle polarized neutron scattering with specular reflected beams.

The speed of microelectronics is currently limited by heating, as increased speed also increases the power dissipation. Spintronics or Spin-Electronics is a new concept allowing for much higher speed. It is based on the manipulation of the electron spins in magnetic layers buried inside the devices. A high magnetization of these magnetic layers is desirable in spintronic devices to allow for efficient manipulation of the electronic states. However, the magnetic moment in promising dilute magnetic oxide nanocomposites is very low, typically corresponding to only fractions of a Bohr magneton for each dopant atom.

In the current project the scientists studied a new type of material consisting of thin TiO2 films with implanted clusters of cobalt. Using the Polarized Neutron Reflectometry at NREX (MLZ) and PLATYPUS (ANSTO, Australia) allowed them to measure the distribution of the magnetic cobalt atoms and showed a large magnetization up to 2.5 μB/Co in the certain Co-rich region. The results of the present study allow to optimize the process parameters of ion implantation of magnetic materials in a non-magnetic matrix to generate the high local magnetizations necessary for multifunctional components in spintronics.

 

Original publication:

David L. Cortie, Yury Khaydukov, Thomas Keller et al., Enhanced Magnetization of Cobalt Defect Clusters Embedded in TiO<sub>2-δ</sub> Films; ACS Appl. Mater. Interfaces 9 (10), 8783 (2017).

 


◄ Back to: News article
To top
  • Privacy
  • Imprint
  • Accessibility